DM10-016NG - NATURAL GAS

Back to Del Mar

DM10-016LP – PROPANE

Problem

Possible Cause

Possible Solution

 

Burner will not light with igniter

Igniter/electrode covered with grease or residue

Clean igniter electrode

   

Igniter/electrode wire loose or disconnected

Check connection & reconnect

   

Wire is shorted causing spark from wire before electrode

 Replace igniter wire

   

No spark being generated

 Replace valve assembly

 

Burner will not light even with match

No gas flow

Check fuel supply

   

Obstructed gas flow

Clean venturi tube and burner

 

Flame goes out

Disconnected gas supply hose

Reconnect gas supply hose

   

High or gusting winds

Place grill out of windy area if possible. Turn front of grill away from the wind

   

Flame on low setting and lid is closed or opened too quickly

Relight and close or open  lid more slowly

 

Flare-up

Excessive cooking temperature

Reduce flame level

   

Grease and/residue build-up

Clean components

   

Excessive fat in meats

Trim fat from cuts of meat before grilling

   

Excessive oils in marinades

Use non-oil based marinades

 

Yellow sooty flame

Excessive cooking temperature

Reduce flame level

 

 

Obstruction of gas flow

Check and clean venturi tube and burner. Check gas supply line connection